| Technical specification | 
				
					| Frequency |  | 
				
					| Frequency Range | 10MHz to 6000MHz | 
				
					| Setting Resolution | 10Hz by direct keyboard entry, or in user-set increments of 10Hz to 999?999MHz by rotary control or increment–decrement keys | 
				
					| Phase Noise | 500MHz Carrier: <-110dBc/Hz @ 20kHz offset; <-120dBc/Hz @ 100kHz | 
				
					|  | 3GHz Carrier: <-95dBc/Hz @ 20kHz offset; <-110dBc/Hz @ 100kHz offset | 
				
					|  | 6GHz Carrier: <-89dBc/Hz @ 20kHz offset; <-104dBc/Hz @ 100kHz offset | 
				
					| Residual FM | Equivalent peak deviation for 300Hz to 3.4kHz B/W: 12Hz at 500MHz carrier | 
				
					| Settling Time | <8ms to settle within 100Hz or 0.1ppm of final frequency, if greater | 
				
					| Reference Frequency | Internal or External (via rear panel BNC) | 
				
					| Internal Accuracy | +/- 1 ppm over 15°C to 30°C; +/- 2 ppm over 5°C to 40°C | 
				
					| Internal Stability | < +/-1ppm/year ageing | 
				
					| Internal Ref. Out | 10MHz from 50 Ohms, amplitude 2V pk-pk into 50 Ohms | 
				
					| External Ref In | 10MHz into 50 Ohms, amplitude 2V pk-pk to 5V pk-pk | 
				
					| Output Level |  | 
				
					| Level Range | –110dBm to +7dBm (0.1μV to 500mV into 50 Ohms) | 
				
					| Setting Resolution | 0.1dB (or 0.01μV to 1mV) by direct keyboard entry, or in user-set increments of 0.1dB to 100dB (or 0.01μV to 100mV) | 
				
					| Accuracy | Better than ± 2dBm | 
				
					| Harmonics | <-25dBc at +7dBm. <-30dBc@levels <=0dBm 30 to 6000MHz, <-25dBc@levels <=0dBm 10 to 30MHz | 
				
					| Sub-Harmonics | <3000MHz : None. >3000MHz :<–40dBc (typ) @ +7dBm | 
				
					| Non-Harmonic Spurii | <–50dBc >10kHz offset 10 to 3000MHz, <-44dBc >10kHz offset 3000MHz to 6000MHz | 
				
					| Output Connector | Type N | 
				
					| Sweep | Frequency and amplitude sweep | 
				
					| Step Sweep | Step frequency and/or amplitude according to a formula over a specified number of points | 
				
					| Dwell Time | Individually programmable 0.01 to 10.000sec per step | 
				
					| Max Points | 1000 | 
				
					| Sweep Run | Continuous or single. Sweep up or down | 
				
					| Step Spacing | Linear or logarithmic | 
				
					| Sweep Triggering | Manual, Ext. signal, timed (0.1 – 999.9sec) or via remote interface | 
				
					| Sync Signal | Output Stable) available during dwell time. Programmable as high or low | 
				
					| List Sweep | As for Step Sweep except that a user defined table of frequency, amplitude and dwell time values defines the steps. The table can be created within the instrument or downloaded via the remote interfaces | 
				
					| Max Points | 1000 | 
				
					| List Storage | Up to 16 Sweep Lists can be stored permanently within the instrument | 
				
					| Point Trigger | Each point in a sweep (step or list) can be subject to a trigger event rather than a dwell time. Trigger by Manual, Ext. signal or via remote interface | 
				
					| Trim | (User Level Compensation Tables) | 
				
					| Function | A table of frequency/gain pairs allows the user to modify the generator output level with respect to frequency to calibrate an entire test set up or improve the calibration of the generator alone | 
				
					| Max Points | 100 | 
				
					| Interfaces | Full digital remote control through the RS232, USB, LAN and GPIB interfaces | 
				
					| RS-232 | 9-pin D connector. Variable Baud rate 1200 and 115200 Baud | 
				
					| USB | USB 2.0 connection. Operates as a virtual COM port | 
				
					| GPIB (IEEE-488) | Conforming with IEEE488.1 and IEEE488.2 | 
				
					| LAN (Ethernet) | Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol | 
				
					| General |  | 
				
					| Size and Weight | 2U (86.5mm) height; half-rack (213mm) width; 350mm long. 3.65 kg. (8 lb) | 
				
					| Power | 110-240VAC ±10% 50/60Hz; 100-120VAC ±10% 400Hz; 60VA max | 
				
					| Approvals | Complies with EN 61010-1 (Safety) and EN61326 (EMC) |